Zhurnal Tekhnicheskoi Fiziki
RUS  ENG    JOURNALS   PEOPLE   ORGANISATIONS   CONFERENCES   SEMINARS   VIDEO LIBRARY   PACKAGE AMSBIB  
General information
Latest issue
Archive
Guidelines for authors

Search papers
Search references

RSS
Latest issue
Current issues
Archive issues
What is RSS



Zhurnal Tekhnicheskoi Fiziki:
Year:
Volume:
Issue:
Page:
Find






Personal entry:
Login:
Password:
Save password
Enter
Forgotten password?
Register


Zhurnal Tekhnicheskoi Fiziki, 2022, Volume 92, Issue 7, Pages 1018–1027
DOI: https://doi.org/10.21883/JTF.2022.07.52659.331-21
(Mi jtf7392)
 

This article is cited in 2 scientific papers (total in 2 papers)

IV International Conference with the School of Young Scientists ''Physics - life science''
Medical monitoring technologies and render

“Pitfalls” in the path of quantitative assessment of the severity of oncological lesions in diagnostic nuclear medicine

A. V. Nesterovaab, N. V. Denisovaab

a Novosibirsk State University, Novosibirsk, Russia
b Khristianovich Institute of Theoretical and Applied Mechanics, Siberian Branch of the Russian Academy of Sciences, Novosibirsk, Russia
Full-text PDF (882 kB) Citations (2)
Abstract: When examining patients by single-photon emission computed tomography, the distribution of a radio-pharmaceutical drug in biological tissues is evaluated. An active fast-growing tumor has an increased uptake of the drug compared to healthy tissues. In recent years, there has been considerable interest in the level of activity of a radiopharmaceutical in tumor lesions, since it can be useful for monitoring the effectiveness of prescribed therapy. To obtain quantitative results, it is necessary that the applied reconstruction algorithms include the main effects that contribute to the formation of images. One of these factors is the geometric resolution of the collimator. It was expected that taking into account this effect would improve the quantitative assessment of tumor lesions in reconstructed images. However, there were “pitfalls” in the way of obtaining quantitative images. In the diagnostic images obtained taking into account the “geometric resolution of the collimator”, so-called edge artifacts were observed, which manifested themselves in the form of a sharp increase in intensity of radiopharmaceutical accumulation in small tumors and as oscillations in the intensity of radiopharmaceutical accumulation at the edges in large tumors. The problem of edge artifacts casts doubt on the correctness of quantitative assessment the level of intensity of drug accumulation in tumor lesions. In this paper, the problem of edge artifacts is investigated using the method of mathematical modeling. In numerical experiments, the dependence of the quantitative estimate of the intensity of RPD accumulation on the parameters of the reconstruction algorithm was investigated for the first time.
Keywords: nuclear medicine, mathematical modeling, single-photon emission computed tomography, edge artifacts.
Received: 29.12.2021
Revised: 29.12.2021
Accepted: 02.03.2022
Bibliographic databases:
Document Type: Article
Language: Russian
Citation: A. V. Nesterova, N. V. Denisova, ““Pitfalls” in the path of quantitative assessment of the severity of oncological lesions in diagnostic nuclear medicine”, Zhurnal Tekhnicheskoi Fiziki, 92:7 (2022), 1018–1027
Citation in format AMSBIB
\Bibitem{NesDen22}
\by A.~V.~Nesterova, N.~V.~Denisova
\paper ``Pitfalls'' in the path of quantitative assessment of the severity of oncological lesions in diagnostic nuclear medicine
\jour Zhurnal Tekhnicheskoi Fiziki
\yr 2022
\vol 92
\issue 7
\pages 1018--1027
\mathnet{http://mi.mathnet.ru/jtf7392}
\crossref{https://doi.org/10.21883/JTF.2022.07.52659.331-21}
\elib{https://elibrary.ru/item.asp?id=48447792}
Linking options:
  • https://www.mathnet.ru/eng/jtf7392
  • https://www.mathnet.ru/eng/jtf/v92/i7/p1018
  • This publication is cited in the following 2 articles:
    Citing articles in Google Scholar: Russian citations, English citations
    Related articles in Google Scholar: Russian articles, English articles
    Zhurnal Tekhnicheskoi Fiziki Zhurnal Tekhnicheskoi Fiziki
     
      Contact us:
     Terms of Use  Registration to the website  Logotypes © Steklov Mathematical Institute RAS, 2025