This article is cited in 5 scientific papers (total in 5 papers)
Reducing power losses in corona discharge under rainfall conditions
K. B. Tynyshtykbaev, G. Zh. Imanbaev, A. M. Ainabaev, Z. A. Insepov Nazarbayev University, Nazarbayev University Research and Innovation System, Astana, Kazakhstan
Abstract:
Aluminum wire of AS300/39 grade with coatings synthesized by micro-arc oxidation in an electrolyte containing additives of graphene oxide and carbon nanotubes was tested under conditions of high-voltage corona discharge in the presence of a model rainfall. It is established that hydrophilic properties of the proposed coating provide for up to 40% reduction in the level of corona power losses.
Received: 09.02.2018
Citation:
K. B. Tynyshtykbaev, G. Zh. Imanbaev, A. M. Ainabaev, Z. A. Insepov, “Reducing power losses in corona discharge under rainfall conditions”, Pisma v Zhurnal Tekhnicheskoi Fiziki, 44:12 (2018), 89–95; Tech. Phys. Lett., 44:6 (2018), 545–547
Linking options:
https://www.mathnet.ru/eng/pjtf5783 https://www.mathnet.ru/eng/pjtf/v44/i12/p89
|
|