Pisma v Zhurnal Tekhnicheskoi Fiziki, 2015, Volume 41, Issue 9, Pages 6–15
(Mi pjtf7702)
|
|
|
|
This article is cited in 26 scientific papers (total in 26 papers)
The use of optical frequency-domain reflectometry in remote distributed measurements of the $\gamma$-radiation dose
A. V. Faustovab, A. I. Gusarova, P. Mégreta, M. Wuilparta, A. V. Zhukovc, S. G. Novikovc, V. V. Svetukhinc, A. A. Fotiadiacd a University of Mons, place du Parc 20, 7000 Mons, Belgium
b SCK · CEN, Boeretang 200, 2400 Mol, Belgium
c Ulyanovsk State University
d Ioffe Institute, St. Petersburg
Abstract:
Results of field measurements of the gamma-radiation dose with a frequency-domain optical reflectometer are presented. The ability to measure doses up to 100 kGy remotely with an accuracy of up to 20% and reconstruct the absorbed dose distribution profile with a resolution of 15 cm for doses up to 9 kGy is demonstrated. The factors affecting the dynamic range and accuracy of measurements are discussed.
Received: 29.10.2014
Citation:
A. V. Faustov, A. I. Gusarov, P. Mégret, M. Wuilpart, A. V. Zhukov, S. G. Novikov, V. V. Svetukhin, A. A. Fotiadi, “The use of optical frequency-domain reflectometry in remote distributed measurements of the $\gamma$-radiation dose”, Pisma v Zhurnal Tekhnicheskoi Fiziki, 41:9 (2015), 6–15; Tech. Phys. Lett., 41:5 (2015), 414–417
Linking options:
https://www.mathnet.ru/eng/pjtf7702 https://www.mathnet.ru/eng/pjtf/v41/i9/p6
|
|