Pisma v Zhurnal Tekhnicheskoi Fiziki, 2014, Volume 40, Issue 6, Pages 82–88
(Mi pjtf8112)
|
|
|
|
This article is cited in 6 scientific papers (total in 6 papers)
The effect of flicker processes on the resolution of self-oscillating magnetometers optically pumped in the saturation regime
S. V. Ermak, P. V. Zimnitsky, R. V. Smolin, V. V. Semenov Peter the Great St. Petersburg Polytechnic University
Abstract:
We present results of calculations of the natural and technical linewidth of a self-oscillating magnetometer with optical pumping of alkali atoms in the saturation regime. Numerical estimations of the technical linewidth of a self-oscillating magnetometer on rubidium isotopes with a common absorption chamber are obtained.
Received: 27.09.2013
Citation:
S. V. Ermak, P. V. Zimnitsky, R. V. Smolin, V. V. Semenov, “The effect of flicker processes on the resolution of self-oscillating magnetometers optically pumped in the saturation regime”, Pisma v Zhurnal Tekhnicheskoi Fiziki, 40:6 (2014), 82–88; Tech. Phys. Lett., 40:3 (2014), 271–273
Linking options: