Pisma v Zhurnal Tekhnicheskoi Fiziki, 2014, Volume 40, Issue 16, Pages 36–41
(Mi pjtf8232)
|
|
|
|
This article is cited in 1 scientific paper (total in 1 paper)
Possibilities of background-radiation-level reduction in proton-therapy rooms
N. A. Ivanov, Zh. S. Lebedeva The Petersburg Nuclear Physics Institute, The National Research Center "Kurchatov Institute"
Abstract:
The system of proton-beam formation for proton ophthalmology has been numerically simulated using the Geant4 program package. Data on the efficiency of narrow- (“pencil”) and wide proton-beam transport are presented. It is established that the use of a wide beam transport is advantageous, since it makes a significant decrease in the background-radiation level in a proton-therapy room possible and simplifies the beam-formation system.
Received: 08.04.2014
Citation:
N. A. Ivanov, Zh. S. Lebedeva, “Possibilities of background-radiation-level reduction in proton-therapy rooms”, Pisma v Zhurnal Tekhnicheskoi Fiziki, 40:16 (2014), 36–41; Tech. Phys. Lett., 40:8 (2014), 693–696
Linking options:
https://www.mathnet.ru/eng/pjtf8232 https://www.mathnet.ru/eng/pjtf/v40/i16/p36
|
|