Vestnik Tomskogo Gosudarstvennogo Universiteta. Matematika i Mekhanika
RUS  ENG    JOURNALS   PEOPLE   ORGANISATIONS   CONFERENCES   SEMINARS   VIDEO LIBRARY   PACKAGE AMSBIB  
General information
Latest issue
Archive
Impact factor

Search papers
Search references

RSS
Latest issue
Current issues
Archive issues
What is RSS



Vestn. Tomsk. Gos. Univ. Mat. Mekh.:
Year:
Volume:
Issue:
Page:
Find






Personal entry:
Login:
Password:
Save password
Enter
Forgotten password?
Register


Vestnik Tomskogo Gosudarstvennogo Universiteta. Matematika i Mekhanika, 2024, Number 89, Pages 162–175
DOI: https://doi.org/10.17223/19988621/89/12
(Mi vtgu1090)
 

This article is cited in 1 scientific paper (total in 1 paper)

MECHANICS

Effective mechanical parameters of bone tissue samples for the selection of individual osteoimplants

T. V. Chaykovskaya

Tomsk State University, Tomsk, Russian Federation
References:
Abstract: The results of the stress-strain state of model bone meso-volumes containing cancellous and cortical bone tissue together and micro-volumes of cortical and cancellous bone tissue separately under uniaxial compression are presented. Unconventional effective mechanical parameters, serving as a relative measure of the deformation response manifestation for the considered meso- or micro-volume of bone in three perpendicular directions, and the effective modulus of elasticity under axial compression are determined. It has been revealed that the micro- and meso-volumes of bone tissue with different structures and compositions may differ in the pattern of stress and strain distribution, but have similar elastic moduli, and vice versa. It has been shown that the micro- and meso-volumes of bone tissue samples with different structures and compositions, having the same distribution of stresses and strains, are characterized by the same values of the introduced effective mechanical parameters. It is proposed to use effective mechanical characteristics and longitudinal modulus of elasticity during the selection and development of individual osteoimplants. When installing an implant into the bone, it is suggested to coordinate the orthotropic axes of the implant and the replaced bone site to maintain a favorable mechanical state of the bone consistent with that before implant installation.
Keywords: stress-strain state, effective mechanical parameters, cortical bone tissue, cancellous bone tissue, computer modeling, osteoimplants.
Received: 30.01.2024
Accepted: June 3, 2024
Document Type: Article
UDC: 531.2
Language: Russian
Citation: T. V. Chaykovskaya, “Effective mechanical parameters of bone tissue samples for the selection of individual osteoimplants”, Vestn. Tomsk. Gos. Univ. Mat. Mekh., 2024, no. 89, 162–175
Citation in format AMSBIB
\Bibitem{Cha24}
\by T.~V.~Chaykovskaya
\paper Effective mechanical parameters of bone tissue samples for the selection of individual osteoimplants
\jour Vestn. Tomsk. Gos. Univ. Mat. Mekh.
\yr 2024
\issue 89
\pages 162--175
\mathnet{http://mi.mathnet.ru/vtgu1090}
\crossref{https://doi.org/10.17223/19988621/89/12}
Linking options:
  • https://www.mathnet.ru/eng/vtgu1090
  • https://www.mathnet.ru/eng/vtgu/y2024/i89/p162
  • This publication is cited in the following 1 articles:
    Citing articles in Google Scholar: Russian citations, English citations
    Related articles in Google Scholar: Russian articles, English articles
    Вестник Томского государственного университета. Математика и механика
     
      Contact us:
     Terms of Use  Registration to the website  Logotypes © Steklov Mathematical Institute RAS, 2025